) Tool
For tightening the terminal, use a
commercially available small
screwdriver having a straight form that is
not widened toward the end as shown
right.
Caution:
If the diameter of screwdriver grip is too
small, tightening torque will not be able
to be achieved. Use the following recommended screwdriver or an
appropriate replacement (grip diameter: approximately 25mm (0.98")).
2 Wiring of Analog Output
→ For the terminal configuration, refer to Subsection 1.2.1
1 Use 2-core shielded twisted pair cable for the analog output lines, and
separate the analog output lines from other power lines or inductive lines.
2 The grounding resistance should be 100Ω or less.
3 Grounding
Grounding should be performed as stated below.
• The grounding resistance should be 100Ω or less.
• Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared
grounding" of the following figure.
→ For details, refer to the FX3G Series User's
Manual - Hardware Edition.
• The grounding wire size should be AWG 22-20 (0.3-0.5 mm2).
• The grounding point should be close to the PLC, and all grounding wire
should be as short as possible.
Manufacturer Model
Phoenix Contact Co., Ltd. SZS 0.4×2.5
With
straight tip
2.5mm
(0.1")
0.4mm
(0.02")
Using voltage
output
1DA-BD
VI-
Terminal
block
V+
I+
Grounding
Using current
output
1DA-BD
VI-
Terminal
block
V+
I+
Grounding
PLC PLC PLC Other
equipment
Shared grounding
Good condition
Common grounding
Not allowed
Independent grounding
Best condition
Other
equipment
Other
equipment
4. Specifications
4.1 Applicable PLC
The version number can be checked by monitoring D8001 as the last three digits
indicate it.
• The number of connectable expansion boards varies depending on the main unit as
follows:
FX3G-14M…, 24M… Main units : 1 unit
FX3G-40M…, 60M… Main units : 2 units
Never stack up two or more expansion boards.
For details on the system configuration, refer to the following manual.
→ Refer to the FX3G/FX3U/FX3UC Series User's Manual - Analog Control Edition
4.2 General Specifications
The general specifications are equivalent to the PLC main unit.
For general specifications, refer to the following manuals.
→ Refer to the FX3G Series User's Manual - Hardware Edition
4.3 Performance Specifications
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric distributor.
• Do not drop the product or exert strong impact to it.
Doing so may cause damage.
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORT AND
STORAGE PRECAUTIONS
• The product is a precision instrument. During transportation, avoid any impacts.
Failure to do so may cause failures in the product. After transportation, verify the
operations of the product.
Model name Applicability
FX3G Series PLC Ver. 1.10 or later
Item
Specifications
Voltage output Current output
Analog output
range
0 to 10V DC
(External load resistance:
2kΩ to 1MΩ)
4 to 20mA DC
(External load resistance:
500Ω or less)
Digital input 12 bits, binary 11 bits, binary
Resolution 2.5mV(10V/4000) 8μA(16mA/2000)
•±0.5%(±50mV) for full scale
of 10V(when ambient
temperature is 25°C±5°C)
•±1.0% (±100mV) for full
scale of 10V
(when ambient temperature
is 0°C to 55°C)
4.4 List of Special Devices
As for the details of the special devices, refer to the following man
→ Refer to the FX3G/FX3U/ FX3UC Series User's Manual - Ana
output
characteristics
0 to 4000 are adjusted to 0 to
10V when the external load
resistance is 2kΩ.
0 to 2000 ar
20mA when
resistance is
Insulation
method No insulation between the PLC.
Occupied
points
0 point (This number is not related to the ma
input/output points of the PLC.)
Device number
Description
BD1 BD2
Special
auxiliary
relay
M8260 M8270
Switches the output mode
OFF: Voltage output ON: Curre
M8264 M8274
Output Holding Function Ca
Setting
OFF: Holds the analog data outp
before stop of the PLC.
ON: Output the offset data at st
PLC.
Special
data
register
D8260 D8270 Output setting data
D8268 D8278
Error status
b0: Output data setting error
b1: Unused
b2: Unused
b3: Unused
b4: EEPROM error
b15 to b5: Unused
D8269 D8279 Model code = 4
Item
Specifications
Voltage output Curr
Analog output
Digital input
0 4080
10V
4000
Analog output
Dig
0
4mA
20mA
立即下載     
相關下載
主站蜘蛛池模板: 国产精品久久国产精麻豆96堂 | 超碰99在线观看 | 国产又粗又爽又深的免费视频 | 精品在线免费播放 | 精品国产91一区二区三区 | 欧美一级爱爱 | 亚洲综合无码一区二区 | 一二区成人影院电影网 | 国产精选电影免费在线观看 | 美女在线观看视频一区二区 | 欧美成人免费 | 黄网站免费观看视频 | 久久在线精品视频 | 久久艳片| 久久久国产精品网站 | 国产三级国产精品国产普男人 | 视屏一区 | 日韩av在线资源 | 欧美无极品 | 深夜视频福利 | 国产成人在线一区 | 成人激情在线 | 一级黄色在线观看 | 免费在线观看国产精品 | 成人免费在线观看视频 | 天天艹综合 | 污片视频网站 | 在线成人一区二区 | www.91视频com | 成人午夜在线免费视频 | 男男羞羞视频网站国产 | 91精品国| 国产精选久久 | 国产人成精品一区二区三 | 视频一区二区在线播放 | 国产一及毛片 | 精品国产一区二区亚洲人成毛片 | 国产精品久久久久无码av | 欧美日韩亚洲国产精品 | 国产激情精品一区二区三区 | 中国免费一级毛片 |